通过RS232进行通信 - VB.net dll / Delphi win32 exe

时间:2011-09-23 08:22:42

标签: vb.net delphi serial-port

我有一个Delphi程序,它与我创建的vb.net dll进行通信。 vb.net dll通过RS232连接与Fluke示波表通信。我创建了一个通过RS232正确通信的程序,给了我预期的价值。但是,当我将它打包为dll并从我的Delphi程序访问dll时,我总是收到值“1”,而不是我期望的值(大多数情况下是240左右的值)。

我知道我的delphi程序肯定与dll正确通信,我的dll肯定是与示波器通信。这只是返回的值,这是问题!希望我在这里做了一些非常愚蠢的事情,但是我看不到它,它开始让我发疯!

这是我的vb.net代码:

Public Interface IFlukeComm
    Function GetReading(ByVal Command As String, ByVal PortNum As Integer) As String
    Function Test() As String
End Interface

Public Class FComm : Implements IFlukeComm

Private WithEvents moRS232 As Rs232
Dim InvokeRequired As Boolean
Dim TxResult As String

Private Sub OpenCom(ByVal PortNum As Integer)
    Dim sTx As String
    moRS232 = New Rs232()
    Try
        With moRS232
            .Port = PortNum
            .BaudRate = 1200
            .DataBit = 8
            .StopBit = Rs232.DataStopBit.StopBit_1
            .Parity = Rs232.DataParity.Parity_None
            .Timeout = 1500
        End With

        moRS232.Open()

        moRS232.Dtr = True
        moRS232.Rts = True
        moRS232.EnableEvents()

        moRS232.PurgeBuffer(Rs232.PurgeBuffers.TxClear Or Rs232.PurgeBuffers.RXClear)
        sTx = "PC 9600"
        sTx += ControlChars.Cr

        moRS232.Write(sTx)

        moRS232.Close()
    Catch ex As Exception

    End Try

End Sub

Private Sub moRS232_CommEvent(ByVal source As Rs232, ByVal Mask As Rs232.EventMasks)       Handles moRS232.CommEvent
    If (Mask And Rs232.EventMasks.RxChar) > 0 Then
        TxResult = source.InputStreamString
    End If
End Sub

Public Function GetReading(ByVal Command As String, ByVal PortNum As Integer) As String     Implements IFlukeComm.GetReading
    OpenCom(PortNum)

    Threading.Thread.Sleep(500)

    With moRS232
        .Port = PortNum
        .BaudRate = 9600
        .DataBit = 8
        .StopBit = Rs232.DataStopBit.StopBit_1
        .Parity = Rs232.DataParity.Parity_None
        .Timeout = 1500
    End With

    moRS232.Open()

    moRS232.Dtr = True
    moRS232.Rts = True
    moRS232.EnableEvents()

    Command += ControlChars.Cr
    moRS232.Write(Command)

    Threading.Thread.Sleep(500)

    moRS232.Close()

    If TxResult <> "" Then
        'moRS232.Read(10)
        Dim sRead As String = moRS232.InputStreamString
        Return sRead
    Else
        Return "Invalid"
    End If
End Function

Public Function Test() As String Implements IFlukeComm.Test
    Return "Success"
End Function

End Class

这是我的Delphi代码:

procedure TfrmLauncher.btnM1UNClick(Sender: TObject);
begin
  ShowMessage(GetMeasurements('QM 11',cmbM1PC.ItemIndex + 1));
end;

function TfrmLauncher.GetMeasurements(strType : string; iPort : Integer) : string;
var
  IFC : IFlukeComm;
begin
  IFC := CreateComObject(CLASS_FComm) as IFlukeComm;
  Result := IFC.GetReading(strType,iPort);
end;

1 个答案:

答案 0 :(得分:0)

TxResult = source.InputStreamString

Dim sRead As String = moRS232.InputStreamString